fr. 09:00 to 18:00 M-F

+38(063)-20-777-39

Connectors electric low-frequency rectangular type 12P

Type of product: Low frequency electrical connectors

Company: OJSC Ltava

Connectors electric low-frequency rectangular type 12P

Designation
Plug (Socket) 12RB (K, G, P) -33 (60) A (B) CE0.364.010 TU, where
12P – type of connector;
Appointment:
B – block:
K – cable;
G – tight;
P – for installation on the panel (instrument);
33 (60) – the number of contacts;
A (B) – type of coating contacts: A – gold; B – silver;
TSE0.364.010 TU – designation of technical conditions.
Climatic modification – UHL in accordance with GOST B 20.39.404-81.

terms of Use
Sinusoidal vibration:
frequency range, Hz 5 – 2500
acceleration amplitude, m / s2 (g) 250 (25)
for block connectors:
frequency range, Hz 5 – 5000
acceleration amplitude, m / s2 (g) 300 (30)
Acoustic noise:
frequency range, Hz 50 – 10000
sound pressure level, dB 150
Repeated mechanical shock:
peak shock acceleration, m / s2 (g) 750 (75)
duration of action, ms 2 – 6
for block connectors:
peak shock acceleration, m / s2 (g) 1500 (150)
duration of action, ms 1 – 3
Mechanical shock single action:
peak shock acceleration, m / s2 (g) 1500 (150)
duration of action, ms 1 – 3
for block connectors:
peak shock acceleration, m / s2 (g) 10000 (1000)
duration of action, ms 0.2 – 1
Linear acceleration, m / s2 (g) 1000 (100)
for block connectors 2000 (200)
Atmospheric reduced working pressure, Pa (mmHg): 1.3 · 10-4 (10-6) Increased working temperature of the medium, ° С 85
Lowered operating temperature, ° С minus 60
Change of temperatures (taking into account the temperature of overheating of contacts), ° С from 115 to minus 60
The increased relative humidity at a temperature of 35 ° C,% 98
Hoarfrost and dew, salt (sea) fog, solar radiation, mold fungi
The shanks of the contacts of the connectors (plugs, sockets) must allow
connection of wires with the maximum cross-section, mm2 0.5
It is recommended to install plugs and sockets with a soft wire cross-section, mm2 0.1 – 0.2

Specifications
Operating current per contact, A 3
Voltage, V (amp) 100
Contact resistance, mOhm, no more than 5
Insulation resistance, MΩ, not less than 1000
Test voltage, V (amp) 500
Capacitance between any contacts, pF, no more than 2
The force of dismemberment of contacts (sockets), with a control caliber, N (kgf) 0.1 (0.01)
Force of dismemberment of connectors, N (kgf), no more than:
for 33-pin connectors 32 (3.2)
for 60-pin connectors 56 (5.6)
The minimum operating time, h 15000
Number of articulations-dissections 500
The minimum shelf life of the connector, 25 years

Contacts