fr. 09:00 to 18:00 M-F

+38(063)-20-777-39

RPA14

Type of product: Relay

Company: SE Factory Radio Relay

The relay has a contact group for telemetry and an interlock, which de-energizes the windings after switching. Magnetic interlock ensures long relay operation with de-energized windings

The relay is available in 3 versions:

RF4.520.000-00 – for operation in coaxial 50-ohm paths with radio frequency connectors corresponding to the socket of drawing 5 VR0.364.015 TU;

RF4.520.000-01 – for mounted and printed mounting;

RF4.520.000-02 – for operation in coaxial 50-ohm paths with radio frequency connectors corresponding to the plug drawing 4 VR0.364.015 TU

Supply voltage, V …………………………………. …………… …. 27 (+9 -7)

Response current, mA ………………………………………….. ……. 120-220

Response time, ms, no more than ………………………………………………… … 15

VSWR for performances

RF4.520.000-00 and RF4.520.000-02: up to 150 MHz ………………………… … … … … 1.25

up to 2000 MHz …………………………… ..1,43

Ambient temperature ……………………………… ..from (minus 60 ° С)

up to (plus 85 ° C)

Atmospheric pressure, mm Hg ……………………………….. from 10-6 to 2300

Winding resistance, Ohm, ……………………………………………… …. 56 ± 5.6

Insulation resistance, megohms, not less than:

under normal conditions …………………………………………. …… .1000

at elevated temperature ………………………………………. ……… .50

at high humidity ………………………………………….. 20

Vibration resistance in the frequency range (from 50 to 2000) Hz … … … … … … … .15g

(from 2000 to 2500) Hz ………………………. 12g

Shock resistance, no more than ……………………………………………… … 150g

Line loads, not more than ……………………………………………… … 100g

Total, or continuous, relay operating time at

elevated temperature, h, no more. …………………………………… .10000

Minimum service life, years …………………………………………. …… .25

The mass of the relay, g, no more …….. ………………………………………. 80

Contacts